BTC-2203C Battery Forced Internal Short Circuit Testing Chamber

Product Detail

Technical Parameter:

Model

BTC-2203C Battery Forced Internal Short Circuit Testing Chamber

Temperature range

-10℃~100℃

Accuracy:

0.1℃

Temperature fluctuation degree

±0.5℃

Temperature uniformity

±2℃

Heating rate

3℃ /min

Cooling speed

1℃ /min

Inner box size

500x500x600mm (L*W*H)

Inner box material

304 stainless steel plate, bottom reinforcement

Outer box size

1050x1500x2100mm (L*W*H)

Temperature control system

Korea imported TEMI system controller

Pressure system

Test load

commonly used 80Kg (maximum 100Kg)

Load resolution

1/10000

Unit conversions

Kg, LB, N

Accuracy

FS≤±0.5%

Resolution

±0.5%

Displacement accuracy

± 0.05mm

Speed range

0.01 ~ 20mm/s, adjustable (commonly used test speed 0.1mm/s)

Effective travel

100mm

Test plane

200X200mm (can be customized)

Voltage acquisition range

0 ~ 20V

Voltage resolution

0.1mv

Voltage acquisition frequency

100 /s

Head size

5x5x2mm or 10x10x2mm or 10x10x15mm

Head material

Nitrile Butadiene rubber, acrylic one piece

Control system

PLC control

 

Product Overview:

Battery forced internal short circuit test machine is simulated battery forced internal short circuit test at a certain temperature, 

test box is made of stainless steel, good temperature uniformity, with exhaust function (i.e. after completion of the test. The 

exhaust emission test) control system of testing machine touch screen menu for PLC, data acquisition frequency up to 100 per 

second, at the same time through the PLC programming test pressure, pressure holding time, pressure,battery voltage,battery 

temperature, pressure drop rate.

 

Standard:

IEC62133-2012,JISC8714-2007,GB 31241-2014,GB/T 18287 -2013,GB/T 8897.6-2008,YD/T 2366.1-2011,GB/T 21966-2008,

MT/T 1051-2007,YD 1268-2003