PPTM-4004C Fabric Tear Strength Tester (Elmendorf method)


 

Product Detail

Technical Parameters:

1. Test Range: 0--16N, 32N, 64N (16000gf, 32000gf, 64000gf) optional

2. Measurement accuracy: ≤±0.2%F·S

3. Unit of measurement: N, cN, gf, lbf

4, sample clamping: pneumatic clamping (air source pressure: 0.6--0.8MPa)

5, the length of the incision: 20mm ± 0.1mm

6, clamp mouth distance: 2.8mm ± 0.3mm

7, dimensions: 480 × 420 × 470mm

8, weight: 55kg

9, power: AC220V 50Hz 100W

 

Application:

PPTM-4004C Fabric Tear Strength Tester (Elmendorf method) is suitable for film, sheet, soft polyvinyl chloride, 

polyvinylidene chloride (PVDC), waterproofing membrane, woven material, polyolefin, polyester, paper, cardboard, 

textile, non-woven fabric, electrical tape. , tear resistance test of materials such as metal foil. The Tear Meter is a powerful, 

multi-industry instrument that has been redesigned to provide a modern look and a range of new features that add value, 

accuracy, safety and flexibility. Winning.

 

Basic applications Plastic film, sheet, such as polyolefin, polyester, aluminum-plastic composite film, etc.

Paper, cardboard

Textile material

 

Extended application

Rubber latex gloves

Stretch film

Paper subway ticket

 

Principle:

Raise the pendulum to a certain height to have a certain potential energy; when the pendulum is free to hem, use its own stored 

energy to tear the sample; the computer control system calculates the energy consumed when tearing the sample,thereby obtaining 

The force required to tear the specimen.

 

Standards:

Plastics: GB/T 11999, ASTM D1922, ISO 6383-2, JIS K 7128-2, NF T54 141

Paper: GB/T 455, APPITA P 400, ASTM D 689, BS 4468, CSA D9, DIN 53128, EN 21974,

ISO 1974, JIS P 8116, PAPTAC D9, SCAN P11, TAPPI T414, UNI 6444

Textiles: GB/T 3917.1, ASTM D1424, DIN 53862, EN ISO 13937-1, ISO 4674-2, ISO 9290, M&S P29, NEXT 17, NF G07-149

Non-woven fabric: ASTM D5734, WSP 100.1


Characteristics:

1. Advanced calculation method (potential energy calculation) to ensure accurate testing and good repeatability.

2, Micro control system, automatic test, calculation, analysis results, print test reports, upload test data.

3,Humanized control system, Chinese and English operation interface, easy to operate, all buttons are function soft keys, 

the operation panel is simple and clear.

4. All data and statistical results can be freely checked in the host.

5. The test unit can choose between N, cN, gf and lbf and automatically convert to meet different standard requirements.

6. The pneumatic sample is clamped to ensure the same clamping force and can reduce the operation intensity. 

The pendulum release effectively avoids the systematic error caused by human factors.

7. Automatically cut the sample to ensure that the shape of the cut is consistent and the operation intensity can be reduced.

8,Equipped with multiple sets of pendulum capacity to meet different test needs of users

Show